Search results for Vendor: GRACE
Found 46 results
Vendor Brand Mode Modification Int. Diam. (mm) Length (mm) Particle (μm) Pore (Å) Columns
GRACE Alltech IC Allsep Anion Anion-Exchange Quaternary ammonium 4 50 – 150 7 3 cols
GRACE Alltech IC Allsep Anion Metal Free Anion-Exchange Quaternary ammonium 4 50 – 150 7 3 cols
GRACE Alltech IC AN1 Anion-Exchange Polystyrene/ Divinylbenzene 4 250 9 1 col
GRACE Alltech IC Anion Exclusion Anion-Exchange Sulfonated polystyrene/ divinylbenzene 7 100 – 300 3 2 cols
GRACE Alltech IC Anion/R Anion-Exchange Polymer/ Triethylammonium 4 100 – 250 10 2 cols
GRACE Alltech IC Anion/S Anion-Exchange Quaternary ammonium 4 100 – 250 10 2 cols
GRACE Alltech IC Novosep A-2 Anion-Exchange Quaternary ammonium 4 250 5 1 col
GRACE Alltech IC Surfactant C18 Anion-Exchange Silica/C18 4 250 5 1 col
GRACE Alltech IC Universal Cation Cation-Exchange Silica/SCX 4 100 7 1 col
GRACE Alltech IC Universal Cation HR Cation-Exchange Silica/SCX 4 – 7 53 – 100 3 2 cols
GRACE Alltech IC Universal Cation Metal Free Cation-Exchange Silica/SCX 4 100 7 1 col
GRACE Alltima HP Amide C18 Reversed-Phase Silica/Amide C18 0 – 4 20 – 250 3 – 5 190 16 cols
GRACE Alltima HP C18 Reversed-Phase Silica/C18 0 – 4 10 – 250 3 – 5 190 22 cols
GRACE Alltima HP C18 AQ Reversed-Phase Silica/C18 0 – 4 10 – 250 3 – 5 100 17 cols
GRACE Alltima HP C18 ESP Reversed-Phase Silica/C18 2 – 4 20 – 250 3 – 5 190 13 cols
GRACE Alltima HP C18 Hi-Load Reversed-Phase Silica/C18 0 – 4 20 – 250 3 – 5 100 16 cols
GRACE Alltima HP C8 Reversed-Phase Silica/C8 0 – 4 20 – 250 3 – 5 190 19 cols
GRACE Alltima HP CN Reversed-Phase Silica/CN 2 – 4 50 – 250 3 – 5 190 10 cols
GRACE Alltima HP HILIC HILIC Silica 0 – 4 10 – 250 1 – 5 120 15 cols
GRACE Alltima HP Silica Reversed-Phase Silica 2 – 4 50 – 250 3 – 5 100 10 cols
GRACE GraceSmart C18 Reversed-Phase Silica/C18 2 – 4 50 – 250 3 – 5 120 10 cols
GRACE Prevail Amino Normal-Phase/Reversed-Phase/Anion-Exchange Silica/Amino 4 50 – 250 3 – 5 110 5 cols
GRACE Prevail C18 Reversed-Phase Silica/C18 2 – 4 50 – 250 3 – 5 110 12 cols
GRACE Prevail C18 Select Reversed-Phase Silica/C18 2 – 4 10 – 250 3 – 5 110 17 cols
GRACE Prevail C8 Reversed-Phase Silica/C8 2 – 4 50 – 250 3 – 5 110 10 cols
GRACE Prevail Cyano Normal-Phase/Reversed-Phase Silica/CN 2 – 4 50 – 250 3 – 5 110 10 cols
GRACE Prevail Organic Acid Reversed-Phase Silica/Organic Acid 2 – 4 100 – 250 3 – 5 110 5 cols
GRACE Prevail Organic Acid Reversed-Phase Polymer/Carbohydrate 4 150 – 250 5 2 cols
GRACE Prevail Phenyl Reversed-Phase Silica/Phenyl 2 – 4 150 – 250 5 110 5 cols
GRACE Prevail Silica Normal-Phase Silica 2 – 4 10 – 250 3 – 5 110 16 cols
GRACE VisionHT C18 Basic Reversed-Phase Silica/C18 1 – 22 20 – 250 1 – 10 120 32 cols
GRACE VisionHT C18 Classic Reversed-Phase Silica/C18 1 – 22 20 – 250 1 – 10 100 32 cols
GRACE VisionHT C18 High Load Reversed-Phase Silica/C18 1 – 22 20 – 250 1 – 10 120 32 cols
GRACE VisionHT C18 Polar Reversed-Phase Silica/C18 1 – 22 20 – 250 1 – 10 100 32 cols
GRACE VisionHT HILIC HILIC Silica 1 – 7 20 – 250 1 – 5 120 20 cols
GRACE VisionHT Silica Reversed-Phase Silica 1 – 4 50 – 250 1 – 5 120 10 cols
GRACE Vydac Everest C18 Reversed-Phase Silica/C18 0 – 4 50 – 250 5 300 21 cols
GRACE Vydac MS C18 Reversed-Phase Silica/C18 0 – 22 50 – 250 3 – 10 300 57 cols
GRACE Vydac MS C4 Reversed-Phase Silica/C4 0 – 22 50 – 250 5 – 10 300 30 cols
GRACE Vydac MS C8 Reversed-Phase Silica/C8 0 – 4 50 – 250 5 300 22 cols
GRACE Vydac MS Diphenyl Reversed-Phase Silica/Diphenyl 2 – 4 100 – 150 5 300 2 cols
GRACE Vydac ProZap C18 Reversed-Phase Silica/C18 2 – 4 10 – 20 1 500 4 cols
GRACE Vydac TP C18 Reversed-Phase Silica/C18 1 – 25 50 – 250 3 – 10 300 39 cols
GRACE Vydac TP C4 Reversed-Phase Silica/C4 1 – 22 50 – 250 3 – 10 300 23 cols
GRACE Vydac TP C8 Reversed-Phase Silica/C8 1 – 22 50 – 250 3 – 10 300 18 cols
GRACE Vydac TP Diphenyl Reversed-Phase Silica/Diphenyl 1 – 22 50 – 250 5 – 10 300 15 cols