Your current column and the selected column, shown together.
5 of 8 scoring criteria are comparable, covering 67% of the total weight. Missing values are excluded.
The percentage includes partial similarity. Green means the recorded values match; red means they differ. The calculation below explains each contribution.
Similarity does not guarantee identical selectivity or performance. Confirm suitability for your method.
| Property | Current columnSepax Technologies Sepax CNT SEC-1000P/N 211000-4605 | Selected columnShodex PROTEIN KWP/N F6989000 |
|---|---|---|
| Vendor | Sepax Technologies≠ Different | Shodex≠ Different |
| Modification | Polymer coated silica✓ Match | Polymer coated silica✓ Match |
| Mode | Size Exclusion✓ Match | Size Exclusion✓ Match |
| Particle Size | 5.0✓ Match | 5.0✓ Match |
| Length | 50≠ Different | 300≠ Different |
| Internal Diameter | 4.6≠ Different | 8.0≠ Different |
| Pore size | 1000≠ Different | 400≠ Different |
| Operating Temperature | 100≠ Different | 45≠ Different |
| pH stability from | 2.0≠ Different | 3.0≠ Different |
| pH stability to | 8.5≠ Different | 7.5≠ Different |
| Brand | Sepax CNT SEC-1000≠ Different | PROTEIN KW≠ Different |
| Max Pressure | Not recorded? Missing or unconfirmed | 725? Missing or unconfirmed |
| Product Usage | Carbon nanotubes≠ Different | Peptides, Polysaccharides, Proteins≠ Different |
Each comparable criterion earns its weight multiplied by its similarity. The sum is divided by the available weight, then multiplied by 100 and rounded. Missing criteria earn no points and add no weight. Vendor, Brand, Mode, length, internal diameter, pressure and temperature do not contribute to this percentage. Mode and Modification determine which families appear in recommendations.
Scroll this table sideways to see both columns and their score contributions. You can also focus the table and use the arrow keys.
| Criterion and method | Current column | Selected column | Contribution |
|---|---|---|---|
| Modification Recorded values overlap. Proprietary modifications are capped at 50%; an identical label does not confirm identical chemistry. | Polymer coated silica | Polymer coated silica | 100.0% × 25 = 25.00 points |
| Product Usage Shared usage values divided by all distinct usage values recorded for these columns. | Carbon nanotubes | Peptides, Polysaccharides, Proteins | 0.0% × 20 = 0.00 points |
| Carbon Load, % Numeric closeness, falling to zero at a 50% relative difference. | Not recorded | Not recorded | Excluded, missing data |
| Endcapping Recorded endcapping values overlap. | Not recorded | Not recorded | Excluded, missing data |
| Pore Size Numeric closeness, falling to zero at a 50% relative difference. | 1000 | 400 | 0.0% × 10 = 0.00 points |
| Surface Area Numeric closeness, falling to zero at a 50% relative difference. | Not recorded | Not recorded | Excluded, missing data |
| pH Stability The overlapping pH range divided by the combined pH range. | 2.0 to 8.5 | 3.0 to 7.5 | 69.2% × 8 = 5.54 points |
| Particle Size Numeric closeness, falling to zero at a 20% relative difference. | 5.0 | 5.0 | 100.0% × 4 = 4.00 points |
34.54 ÷ 67 × 100 = 52% (rounded).