Column comparison

Your current column and the selected column, shown together.

79%Weighted similarity

6 of 8 scoring criteria are comparable, covering 72% of the total weight. Missing values are excluded.

The percentage includes partial similarity. Green means the recorded values match; red means they differ. The calculation below explains each contribution.

Similarity does not guarantee identical selectivity or performance. Confirm suitability for your method.

✓ Matching values≠ Different values? Missing or unconfirmed
Recorded specifications of the current and selected columns
Property Current columnGreyhound Spheripak ODS1 80P/N 20-105810 Selected columnGRACE VisionHT C18 PolarP/N 5139556
VendorGreyhound≠ DifferentGRACE≠ Different
ModificationSilica/C18✓ MatchSilica/C18✓ Match
ModeReversed-Phase✓ MatchReversed-Phase✓ Match
Particle Size10.0≠ Different1.5≠ Different
Length100≠ Different20≠ Different
Internal Diameter4.0≠ Different1≠ Different
Pore size80≠ Different100≠ Different
Surface Area220≠ Different200≠ Different
Carbon Load, %6.2≠ Different5≠ Different
EndcappedNo✓ MatchNo✓ Match
BrandSpheripak ODS1 80≠ DifferentVisionHT C18 Polar≠ Different
pH stability fromNot recorded? Missing or unconfirmed1? Missing or unconfirmed
pH stability toNot recorded? Missing or unconfirmed10? Missing or unconfirmed
Product UsageNot recorded? Missing or unconfirmedAcidic compounds, Aromatic compounds, Basic compounds, Environmental samples, Organic acids, Polar compounds, Small molecules? Missing or unconfirmed

How this similarity score is calculated

Each comparable criterion earns its weight multiplied by its similarity. The sum is divided by the available weight, then multiplied by 100 and rounded. Missing criteria earn no points and add no weight. Vendor, Brand, Mode, length, internal diameter, pressure and temperature do not contribute to this percentage. Mode and Modification determine which families appear in recommendations.

Scroll this table sideways to see both columns and their score contributions. You can also focus the table and use the arrow keys.

Score contributions for the exact two columns
Criterion and methodCurrent columnSelected columnContribution
Modification
Recorded values overlap. Proprietary modifications are capped at 50%; an identical label does not confirm identical chemistry.
Silica/C18Silica/C18100.0% × 25 = 25.00 points
Product Usage
Shared usage values divided by all distinct usage values recorded for these columns.
Not recordedAcidic compounds, Aromatic compounds, Basic compounds, Environmental samples, Organic acids, Polar compounds, Small moleculesExcluded, missing data
Carbon Load, %
Numeric closeness, falling to zero at a 50% relative difference.
6.2561.3% × 15 = 9.19 points
Endcapping
Recorded endcapping values overlap.
NoNo100.0% × 10 = 10.00 points
Pore Size
Numeric closeness, falling to zero at a 50% relative difference.
8010060.0% × 10 = 6.00 points
Surface Area
Numeric closeness, falling to zero at a 50% relative difference.
22020081.8% × 8 = 6.55 points
pH Stability
The overlapping pH range divided by the combined pH range.
Not recorded1 to 10Excluded, missing data
Particle Size
Numeric closeness, falling to zero at a 20% relative difference.
10.01.50.0% × 4 = 0.00 points

56.74 ÷ 72 × 100 = 79% (rounded).

Advertise With Us

Reach thousands of HPLC scientists and researchers. Fill in your details and our team will contact you shortly.