Intrada WP-RP

– 66 columns
Vendor: Imtakt

 

Improved Protein Recovery for Polymer Separation
 
* Reverse-column tailored with a 30nm pore size
* Optimal for the separation of proteins and oteher large molecules up to 300'000 Da
 
Low Carryover
 
* Unique packing reduces carryover
 
Superiour Resolution Column with 3µm Particles
 
* High Resolution 3µm Silicia is used
* Radically improved column efficiancy compared with conventional 5µm columns
 
Optimal Surface Polarity for Faster Polymer Elution
 
* Uses a newly developed reverse phase ligand
* Highly hidrophobic polymer elution made possible by optimal surface polarity

Brand specifications

Every parameter recorded for every column in this Brand is shown here. A single value applies across the Brand; multiple values show what is recorded across its columns.

Mode Reversed-Phase Max Pressure 3625 / 3626
Modification Silica/Alkyl / Silica/C18 Operating Temperature 65
Pore Size (Å) 300 pH stability from 2.0
Surface Area 100 pH stability to 7.0
Endcapped Yes

Choose column specifications

Available: 30 – 500 mm
Available: 0.1 – 10 mm
Particle Size Recorded value 3 μm
Pore Size Recorded value 300 Å

Columns in this brand

Use the selectors above to narrow the list by specification, or search here by P/N or any displayed value.

66 columns shown
WPR01 30 4.6 3.0 300
WPR02 50 4.6 3.0 300
WPR03 75 4.6 3.0 300
WPR04 100 4.6 3.0 300
WPR05 150 4.6 3.0 300
WPR06 250 4.6 3.0 300
WPR07 500 4.6 3.0 300
WPR11 30 1.0 3.0 300
WPR12 50 1.0 3.0 300
WPR13 75 1.0 3.0 300
WPR14 100 1.0 3.0 300
WPR15 150 1.0 3.0 300
WPR16 250 1.0 3.0 300
WPR21 30 2.0 3.0 300
WPR22 50 2.0 3.0 300
WPR23 75 2.0 3.0 300
WPR24 100 2.0 3.0 300
WPR25 150 2.0 3.0 300
WPR26 250 2.0 3.0 300
WPR31 30 3.0 3.0 300
WPR32 50 3.0 3.0 300
WPR33 75 3.0 3.0 300
WPR34 100 3.0 3.0 300
WPR35 150 3.0 3.0 300
WPR36 250 3.0 3.0 300
WPR61 30 6.0 3.0 300
WPR62 50 6.0 3.0 300
WPR63 75 6.0 3.0 300
WPR64 100 6.0 3.0 300
WPR65 150 6.0 3.0 300
WPR66 250 6.0 3.0 300
WPR71 30 1.5 3.0 300
WPR72 50 1.5 3.0 300
WPR73 75 1.5 3.0 300
WPR74 100 1.5 3.0 300
WPR75 150 1.5 3.0 300
WPR76 250 1.5 3.0 300
WPRD2 50 0.5 3.0 300
WPRD4 100 0.5 3.0 300
WPRD5 150 0.5 3.0 300
WPRD6 250 0.5 3.0 300
WPRF2 50 0.3 3.0 300
WPRF4 100 0.3 3.0 300
WPRF5 150 0.3 3.0 300
WPRF6 250 0.3 3.0 300
WPRH2 50 0.2 3.0 300
WPRH4 100 0.2 3.0 300
WPRH5 150 0.2 3.0 300
WPRH6 250 0.2 3.0 300
WPRJ2 50 0.2 3.0 300
WPRJ4 100 0.2 3.0 300
WPRJ5 150 0.2 3.0 300
WPRJ6 250 0.2 3.0 300
WPRL2 50 0.1 3.0 300
WPRL4 100 0.1 3.0 300
WPRL5 150 0.1 3.0 300
WPRL6 150 0.1 3.0 300
WPRM2 50 0.1 3.0 300
WPRM4 100 0.1 3.0 300
WPRM5 150 0.1 3.0 300
WPRM6 150 0.1 3.0 300
WPRP1 30 10.0 3.0 300
WPRP2 50 10.0 3.0 300
WPRP3 75 10.0 3.0 300
WPRP4 100 10.0 3.0 300
WPRP5 150 10.0 3.0 300
No columns match these filters. Clear one or more filters to see other options.
Advertise With Us