PROTO 300 C4

– 58 columns
Vendor: Higgins Analytical

PROTO 300 Analytical Columns - Stainless Steel

Low pH operating conditions and high pH column washing steps are typical bioprocessing operating conditions that can severely limit the lifetime and performance of widepore columns typically used for protein and peptide analysis. Higgins Analytical’s new PROTO300 has high capacity for enhanced resolution and is robust enough to withstand prolonged use at extreme pH (1.5 - 10).

Brand specifications

Every parameter recorded for every column in this Brand is shown here. A single value applies across the Brand; multiple values show what is recorded across its columns.

Mode Reversed-Phase Carbon Load, % 3.0
Modification Silica/C4 Endcapped Yes
Pore Size (Å) 300 pH stability from 1.5
Surface Area 100 pH stability to 10.0

Choose column specifications

Available: 30 – 250 mm
Available: 0.075 – 20 mm
Available: 5 – 10 μm
Pore Size Recorded value 300 Å

Columns in this brand

Use the selectors above to narrow the list by specification, or search here by P/N or any displayed value.

58 columns shown
RC-2507-W045 250 0.075 5.0 300
RC-2515-W045 250 0.15 5.0 300
RS-0301-W045 30 1.0 5.0 300
RS-0321-W045 30 2.1 5.0 300
RS-0330-W045 30 3.0 5.0 300
RS-0340-W045 30 4.0 5.0 300
RS-0346-W045 30 4.6 5.0 300
RS-03M3-W045 30 0.3 5.0 300
RS-03M5-W045 30 0.5 5.0 300
RS-03M8-W045 30 0.8 5.0 300
RS-0501-W045 50 1.0 5.0 300
RS-0510-W041 50 10.0 10.0 300
RS-0510-W045 50 10.0 5.0 300
RS-0520-W041 50 20.0 10.0 300
RS-0520-W045 50 20.0 5.0 300
RS-0521-W045 50 2.1 5.0 300
RS-0530-W045 50 3.0 5.0 300
RS-0540-W045 50 4.0 5.0 300
RS-0546-W045 50 4.6 5.0 300
RS-05M3-W045 50 0.3 5.0 300
RS-05M5-W045 50 0.5 5.0 300
RS-05M8-W045 50 0.8 5.0 300
RS-1001-W045 100 1.0 5.0 300
RS-1010-W041 100 10.0 10.0 300
RS-1010-W045 100 10.0 5.0 300
RS-1020-W041 100 20.0 10.0 300
RS-1020-W045 100 20.0 5.0 300
RS-1021-W045 100 2.1 5.0 300
RS-1030-W045 100 3.0 5.0 300
RS-1040-W045 100 4.0 5.0 300
RS-1046-W045 100 4.6 5.0 300
RS-10M3-W045 100 0.3 5.0 300
RS-10M5-W045 100 0.5 5.0 300
RS-10M8-W045 100 0.8 5.0 300
RS-1501-W045 150 1.0 5.0 300
RS-1510-W041 150 10.0 10.0 300
RS-1510-W045 150 10.0 5.0 300
RS-1520-W041 150 20.0 10.0 300
RS-1520-W045 150 20.0 5.0 300
RS-1521-W045 150 2.1 5.0 300
RS-1530-W045 150 3.0 5.0 300
RS-1540-W045 150 4.0 5.0 300
RS-1546-W045 150 4.6 5.0 300
RS-15M3-W045 150 0.3 5.0 300
RS-15M5-W045 150 0.5 5.0 300
RS-15M8-W045 150 0.8 5.0 300
RS-2501-W045 250 1.0 5.0 300
RS-2510-W041 250 10.0 10.0 300
RS-2510-W045 250 10.0 5.0 300
RS-2520-W041 250 20.0 10.0 300
RS-2520-W045 250 20.0 5.0 300
RS-2521-W045 250 2.1 5.0 300
RS-2530-W045 250 3.0 5.0 300
RS-2540-W045 250 4.0 5.0 300
RS-2546-W045 250 4.6 5.0 300
RS-25M3-W045 250 0.3 5.0 300
RS-25M5-W045 250 0.5 5.0 300
RS-25M8-W045 250 0.8 5.0 300
No columns match these filters. Clear one or more filters to see other options.