HECTOR-ACD WCX

– 59 columns
Vendor: RSTech

HECTOR-ACD WCX (Weak Cation Exchange type)

To separate acidic compounds using normal-phase bare silica gel, the addition of acid to the solution is necessary. There is no problem with the use of a pH buffer as an agent in the case of analytical separation, but when performing preparative separation, the pH-buffering agent must be removed later in the process. As HECTOR-ACD WCX with an “immobilized-acid functional group” works just as well as a buffer, however, there is no need to add a TFA buffer.

Brand specifications

Every parameter recorded for every column in this Brand is shown here. A single value applies across the Brand; multiple values show what is recorded across its columns.

Mode Ion Exchange Carbon Load, % 6.5
Modification Silica/WCX Endcapped Yes
Pore Size (Å) 100

Choose column specifications

Available: 50 – 250 mm
Available: 2.1 – 21.2 mm
Available: 3 – 10 μm
Pore Size Recorded value 100 Å

Columns in this brand

Use the selectors above to narrow the list by specification, or search here by P/N or any displayed value.

59 columns shown
WCX-1010010100 100 10.0 10.0 100
WCX-1010010200 100 21.2 10.0 100
WCX-101001046 100 4.6 10.0 100
WCX-1010015100 150 10.0 10.0 100
WCX-1010015200 150 21.2 10.0 100
WCX-101001546 150 4.6 10.0 100
WCX-1010025100 250 10.0 10.0 100
WCX-1010025200 250 21.2 10.0 100
WCX-101002546 250 4.6 10.0 100
WCX-310005100 50 10.0 3.0 100
WCX-31000521 50 2.1 3.0 100
WCX-31000530 50 3.0 3.0 100
WCX-31000539 50 3.9 3.0 100
WCX-31000546 50 4.6 3.0 100
WCX-310007100 70 10.0 3.0 100
WCX-31000721 70 2.1 3.0 100
WCX-31000730 70 3.0 3.0 100
WCX-31000739 70 3.9 3.0 100
WCX-31000746 70 4.6 3.0 100
WCX-310010100 100 10.0 3.0 100
WCX-31001021 100 2.1 3.0 100
WCX-31001030 100 3.0 3.0 100
WCX-31001039 100 3.9 3.0 100
WCX-31001046 100 4.6 3.0 100
WCX-310015100 150 10.0 3.0 100
WCX-31001521 150 2.1 3.0 100
WCX-31001530 150 3.0 3.0 100
WCX-31001539 150 3.9 3.0 100
WCX-31001546 150 4.6 3.0 100
WCX-31002521 250 2.1 3.0 100
WCX-31002530 250 3.0 3.0 100
WCX-31002539 250 3.9 3.0 100
WCX-31002546 250 4.6 3.0 100
WCX-510005100 50 10.0 5.0 100
WCX-510005200 50 21.2 5.0 100
WCX-51000521 50 2.1 5.0 100
WCX-51000530 50 3.9 5.0 100
WCX-51000539 50 3.9 5.0 100
WCX-51000546 50 4.6 5.0 100
WCX-510007100 70 10.0 5.0 100
WCX-510007200 70 21.2 5.0 100
WCX-51000721 70 2.1 5.0 100
WCX-51000730 70 3.0 5.0 100
WCX-51000739 70 3.9 5.0 100
WCX-51000746 70 4.6 5.0 100
WCX-510010100 100 10.0 5.0 100
WCX-510010200 100 21.2 5.0 100
WCX-510015100 150 10.0 5.0 100
WCX-510015200 150 21.2 5.0 100
WCX-51001521 150 2.1 5.0 100
WCX-51001530 150 3.0 5.0 100
WCX-51001539 150 3.9 5.0 100
WCX-51001546 150 4.6 5.0 100
WCX-510025100 250 10.0 5.0 100
WCX-510025200 250 21.2 5.0 100
WCX-51002521 250 2.1 5.0 100
WCX-51002530 250 3.0 5.0 100
WCX-51002539 250 3.9 5.0 100
WCX-51002546 250 4.6 5.0 100
No columns match these filters. Clear one or more filters to see other options.