Original ZORBAX

– 52 columns
Vendor: Agilent Technologies

ZORBAX Original Reversed-Phase HPLC Columns   
 
 ZORBAX Original Reversed-Phase columns are made with Type A silica and are useful for many separations of acidic or neutral compounds. These columns have a higher activity level and are therefore useful for separating isomers (e.g. cis-trans, geometric) or other compounds where silanol activity enhances selectivity. These columns are used in many established methods. 

  • High surface area (300 m²/g, 20% carbon load for C18) gives added retention
  • Uses the original ZORBAX SIL support, monolayer silane bonding, and single endcapping for deactivation of silanol groups
  • High-strength porous silica microsphere technology allows high pressure packing and high plate counts (16,000 - 20,000 plates/ 4.6 x 250mm column)
  • Low backpressure due to narrow particle size distribution
  • In-house silica manufacture insures reproducibility

Brand specifications

Every parameter recorded for every column in this Brand is shown here. A single value applies across the Brand; multiple values show what is recorded across its columns.

Mode Normal-Phase / Normal-Phase/Reversed-Phase / Reversed-Phase Surface Area 180 / 300
Modification Silica / Silica/Amino / Silica/C18 / Silica/C8 / Silica/CN / Silica/Phenyl / Silica/TMS pH stability from 1.0 / 2.0
Pore Size (Å) 70 / 80 pH stability to 7.0 / 8.0 / 9.0

Choose column specifications

Available: 50 – 250 mm
Available: 2 – 21 mm
Available: 3 – 7 μm
Available: 70 – 80 Å

Columns in this brand

Use the selectors above to narrow the list by specification, or search here by P/N or any displayed value.

52 columns shown
860700-708 50 2.0 5.0 70
861767-902 100 2.0 3.5 80
861967-302 100 3.0 3.5 80
861967-902 100 4.0 3.5 80
863967-302 150 3.0 3.5 80
863967-902 150 4.0 3.5 80
866967-902 75 4.0 3.5 80
877952-102 250 21.0 7.0 70
877952-105 250 21.0 7.0 70
877952-106 250 21.0 7.0 70
877952-108 250 21.0 7.0 70
877967-102 250 21.0 7.0 80
880952-101 250 21.0 7.0 70
880952-102 250 21.0 7.0 70
880952-105 250 21.0 7.0 70
880952-106 250 21.0 7.0 70
880952-108 250 21.0 7.0 70
880952-201 250 9.0 5.0 70
880952-202 250 9.0 5.0 70
880952-205 250 9.0 5.0 70
880952-206 250 9.0 5.0 70
880952-208 250 9.0 5.0 70
880952-210 250 9.0 5.0 70
880952-212 250 9.0 5.0 70
880952-302 250 3.0 5.0 70
880952-701 250 4.0 5.0 70
880952-702 250 4.0 5.0 70
880952-705 250 4.0 5.0 70
880952-706 250 4.0 5.0 70
880952-708 250 4.0 5.0 70
880952-710 250 4.0 5.0 70
880952-712 250 4.0 5.0 70
880953-901 80 6.0 3.0 70
880967-102 250 21.0 7.0 80
880967-202 250 9.0 5.0 80
880967-302 250 3.0 5.0 80
880967-902 250 4.0 5.0 80
883700-902 150 2.0 5.0 80
883952-302 150 3.0 5.0 70
883952-701 150 4.0 5.0 70
883952-702 150 4.0 5.0 70
883952-705 150 4.0 5.0 70
883952-706 150 4.0 5.0 70
883952-708 150 4.0 5.0 70
883952-710 150 4.0 5.0 70
883952-712 150 4.0 5.0 70
883967-302 150 3.0 5.0 80
883967-902 150 4.0 5.0 80
884950-507 250 4.0 5.0 70
884950-526 150 4.0 5.0 70
884950-543 250 4.0 5.0 70
884950-556 250 4.0 5.0 70