Product no. 03B-4378-N0
Get quote
Catalog Luna NH2 03B-4378-N0

Select an image to enlarge and zoom.

03B-4378-N0 images

Zoom in to see detail, then drag or scroll. Press Escape to close.

Price / Quotation
Price on request

Luna NH2

by Phenomenex

One of the World's Leading HPLC Columns

Dependable, ultra-pure silica-based HPLC columns that offer an extensive variety of selectivities which are scalable from micro-bore to preparative and purification scale solutions.

  • Extensive line of rugged USP phases
  • Wide pH stability for long column lifetime and method flexibility
  • Easy method scalability from Fast LC to Preparative and Bulk Purification

Amino groups bound to the silica surface serve as a weak anion exchanger and offer polar selectivity under reversed phase and normal phase conditions.

Specification

View this column family
Vendor Phenomenex Particle Size 5.0
Brand Luna NH2 Length 50
Modifification Silica/Amino Internal Diameter 10.0
Mode Normal-Phase Pore size 100

Product Usage

Polar compounds

Applications of column use

No Applications are assigned to this Product.

Similar columns from other manufacturers to Luna NH2

Specific columns from up to 10 families from other manufacturers with the same Mode and Modification. Compare a column to see its recorded specifications alongside this column.

How similarity is calculated
The percentage compares the two specific columns shown, using Modification (25%), Product Usage (20%), Carbon Load (15%), Endcapping (10%), Pore Size (10%), Surface Area (8%), pH Stability (8%) and Particle Size (4%). Missing values are excluded. At least three criteria and 50% of the total weight must be available to show a score. Open Compare Column for every contribution and the calculation. Mode is a required discovery filter; length and internal diameter do not affect the score. Recommendations retain the family discovery rules. An eligible sponsor may appear first and is labelled Sponsored.
A similarity score does not guarantee identical selectivity or performance. Confirm suitability under the intended method conditions.
HECTOR-M NH2
by RSTech
P/N NH2-M1010010100
59% similarity
ModeNormal-Phase
ModificationSilica/Amino
Pore Size100
Shared Product UsageNo shared usage recorded
Inertsil NH2
by GL Sciences
P/N 5020-11521
59% similarity
ModeNormal-Phase
ModificationSilica/Amino
Pore Size100
Shared Product UsageNo shared usage recorded

Customer feedback

No customer reviews yet. Be the first to share your experience!

Advertise With Us

Reach thousands of HPLC scientists and researchers. Fill in your details and our team will contact you shortly.