| Vendor | Brand | Mode | Modification | Length (mm) | Int. Diam. (mm) | Particle (μm) | Pore (Å) | Columns |
|---|---|---|---|---|---|---|---|---|
| Bonna-Agela Technologies | Bonshell ASB C18 | Reversed-Phase | Silica/C18 | 30 – 100 | 2.1 – 4.6 | 2.7 | 90 | 9 cols |
| Bonna-Agela Technologies | Bonshell C18 | Reversed-Phase | Silica/C18 | 30 – 100 | 2.1 – 4.6 | 2.7 | 90 | 9 cols |
| Bonna-Agela Technologies | Durashell C18 | Reversed-Phase | Silica/C18 | 10 – 250 | 2.1 – 50 | 3 – 10 | 100 | 46 cols |
| Bonna-Agela Technologies | Durashell C18 (L) | Reversed-Phase | Silica/C18 | 10 – 250 | 2.1 – 50 | 3 – 10 | 150 | 46 cols |
| Bonna-Agela Technologies | Durashell C8 | Reversed-Phase | Silica/C8 | 10 – 250 | 2.1 – 50 | 3 – 10 | 100 | 46 cols |
| Bonna-Agela Technologies | Durashell NH2 | Normal-Phase/HILIC | Silica/Amino | 10 – 250 | 2.1 – 50 | 3 – 10 | 100 | 46 cols |
| Bonna-Agela Technologies | Durashell RP | Reversed-Phase | Silica/C18 | 10 – 250 | 2.1 – 50 | 3 – 10 | 150 | 46 cols |
| Bonna-Agela Technologies | Not assigned | Normal-Phase/Reversed-Phase/HILIC | Silica/Amide | 30 | 2.1 | 3 | 100 | 1 col |
| Bonna-Agela Technologies | Optimix C18/Amide | Reversed-Phase | Silica/Amide C18 | 30 – 250 | 2.1 – 4.6 | 3 – 5 | 100 | 16 cols |
| Bonna-Agela Technologies | Optimix C18/C8 | Reversed-Phase | Silica/C18+C8 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 9 cols |
| Bonna-Agela Technologies | Optimix C18/Nitrophenyl | Reversed-Phase | Silica/C18/Nitrophenyl | 30 – 250 | 2.1 – 4.6 | 5 | — | 9 cols |
| Bonna-Agela Technologies | Optimix C18/Phenyl | Reversed-Phase | Silica/C18/Phenyl | 30 – 250 | 2.1 – 4.6 | 5 | — | 9 cols |
| Bonna-Agela Technologies | Optimix C18/SAX | Reversed-Phase+AX | Silica/C18+SAX | 30 – 250 | 2.1 – 4.6 | 5 | — | 9 cols |
| Bonna-Agela Technologies | Optimix C18/SCX | Reversed-Phase+CX | Silica/C18+SCX | 30 – 250 | 2.1 – 4.6 | 3 – 5 | — | 16 cols |
| Bonna-Agela Technologies | Promosil C18 | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | Promosil C8 | Reversed-Phase | Silica/C8 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | Promosil CN | Normal-Phase/Reversed-Phase/HILIC | Silica/CN | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | Promosil NH2 | Normal-Phase/Reversed-Phase/HILIC | Silica/Amino | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | Promosil Silica | Normal-Phase/Reversed-Phase/HILIC | Silica | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | UHP AQ C18 | Reversed-Phase | Silica/C18 | 30 – 100 | 2.1 – 4.6 | 1.9 | 100 | 12 cols |
| Bonna-Agela Technologies | UHP ASB C18 | Reversed-Phase | Silica/C18 | 30 – 100 | 2.1 – 4.6 | 1.9 | 100 | 12 cols |
| Bonna-Agela Technologies | UHP HILIC | HILIC | Not assigned | 30 – 100 | 2.1 – 4.6 | 1.9 | 100 | 12 cols |
| Bonna-Agela Technologies | UHP Innoval C18 | Reversed-Phase | Silica/C18 | 30 – 100 | 2.1 – 4.6 | 1.9 | 100 | 12 cols |
| Bonna-Agela Technologies | Unisol Amide | Normal-Phase/Reversed-Phase/HILIC | Silica/Amide | 30 – 250 | 2.1 – 50 | 3 – 10 | 100 | 32 cols |
| Bonna-Agela Technologies | Unisol C18 | Reversed-Phase | Silica/C18 | 30 – 250 | 0.5 – 50 | 2.5 – 10 | 100 | 49 cols |
| Bonna-Agela Technologies | Venusil AQ C18 | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 50 | 3 – 10 | 100 | 29 cols |
| Bonna-Agela Technologies | Venusil ASB C18 | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 50 | 3 – 10 | 150 – 300 | 59 cols |
| Bonna-Agela Technologies | Venusil ASB C8 | Reversed-Phase | Silica/C8 | 30 – 250 | 2.1 – 50 | 3 – 10 | 150 – 300 | 59 cols |
| Bonna-Agela Technologies | Venusil HLP | Reversed-Phase | Silica/ Alkylamide | 50 – 250 | 4.6 | 5 | 100 | 5 cols |
| Bonna-Agela Technologies | Venusil PAH | Reversed-Phase | Silica/modified for PAH | 250 | 4.6 | 5 | 200 | 1 col |
| Bonna-Agela Technologies | Venusil PFP | Reversed-Phase | Silica/PFP | 50 – 250 | 4.6 | 5 | 120 | 5 cols |
| Bonna-Agela Technologies | Venusil SAX | Anion-Exchange | Silica/SAX | 50 – 250 | 4.6 | 5 | 100 | 5 cols |
| Bonna-Agela Technologies | Venusil SAX (T) | Anion-Exchange | Silica/SAX | 50 – 250 | 4.6 | 5 | 300 | 5 cols |
| Bonna-Agela Technologies | Venusil SCX | Cation-Exchange | Silica/SCX | 50 – 250 | 4.6 | 5 | 150 | 5 cols |
| Bonna-Agela Technologies | Venusil SCX (T) | Cation-Exchange | Silica/SCX | 50 – 250 | 4.6 | 5 | 300 | 5 cols |
| Bonna-Agela Technologies | Venusil XBP C1 | Reversed-Phase | Silica/C1 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 9 cols |
| Bonna-Agela Technologies | Venusil XBP C18 | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 50 | 3 – 10 | 100 | 34 cols |
| Bonna-Agela Technologies | Venusil XBP C18(L) | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 4.6 | 5 | 150 | 8 cols |
| Bonna-Agela Technologies | Venusil XBP C4 | Reversed-Phase | Silica/C4 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 9 cols |
| Bonna-Agela Technologies | Venusil XBP C8 | Reversed-Phase | Silica/C8 | 30 – 250 | 2.1 – 50 | 3 – 10 | 100 | 34 cols |
| Bonna-Agela Technologies | Venusil XBP C8(L) | Reversed-Phase | Silica/C8 | 30 – 250 | 2.1 – 4.6 | 5 | 150 | 8 cols |
| Bonna-Agela Technologies | Venusil XBP COOH | Cation-Exchange | Silica/ Carboxylic acid | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |
| Bonna-Agela Technologies | Venusil XBP Silica | Normal-Phase | Silica | 30 – 250 | 2.1 – 4.6 | 5 | 150 | 8 cols |
| Bonna-Agela Technologies | Venusil XBP-C18 (2) | Reversed-Phase | Silica/C18 | 30 – 250 | 2.1 – 4.6 | 5 | 100 | 8 cols |